1. Blastproof Glass System: Explosion and Blast Resistance Performance
Standards | TR1 | TR2 | TR3 | notes | |
European Standards |
EN13123-2 Windows, doors, and shutters —Explosion resistance —Requirements and classification — Part 2: Range test |
EXR1- EXR5* (customized) EXR1=3kg TNT -5-meter explosion EXR2=3kg TNT -3-meter explosion EXR3=12kg TNT - Explosion in 5.5 meters EXR4=12kg TNT - 4-meter explosion EXR5=20kg TNT - Explosion in 5.5 meters |
Note*: EXR is the serial number specified in EN13123-2. You can customize your own products based on local engineering requirements. |
2. More Performances: Building physics
Besides KFORTS high security performance, TR system complies with all requirements in building physics up to highest level. It features a slim frame, a concealed sash design, and a wide visible area.
Resistance against wind load |
Water tightness |
Air permeability |
Technical parameters: ≥ 16kpa/m ³ (1800 * 1500), | Technical parameters: ≥ 700 (PA), | Technical parameters: The unit seam length index value is ≤ 0.5m ³ (m · h),The unit area index value is ≤ 1.4 square meters (m · h),Level: 8 (max). |
Air permeability |
Sound Insulation |
Standard: EN673 | Standard: GB/T 8485-2008, |
Technical parameters: 1.87-2.15 W/(㎡· k) Door: 2.158 W/(㎡· k) Window: 1.875 W/(㎡· k) Curtain Wall: 1.873 W/(㎡· k) |
Technical parameters: ≥ 45 (dB (A)), |
3. Design and Sections
TR Security Glass Window System
Design examples
Single leaf:
Minimum Size: Width = 500mm, Height = 750mm
Maximum Size: Width = 800mm, Height = 1800mm
Fixed panel:
Minimum Size: Width = 400mm, Height = 400mm
Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.
TR Security Glass Window System
Section Examples
Types |
Thickness of bullet proof steel plate/mm |
Thickness of Glass/mm |
EN1627-EN1630 Forced entry resistance |
EN1063 Bullet resistance |
UL752 Bullet resistance |
TRW-1
|
2.5-15
|
47.5-70
|
RC3
|
B1-B7
|
Level 1-8
|
TRW-2
|
RC4
|
||||
TRW-3
|
RC6
|
TR Security Glass Swing Door and Curtain Wall System
Design examples
Single leaf:
Minimum Size: Width = 600mm, Height = 1500mm
Maximum Size: Width = 1000mm, Height = 2500mm
Fixed panel:
Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.
TR Security Glass Swing Door and Curtain Wall System
Section examples
Types |
Thickness of bullet proof steel plate/mm |
Thickness of Glass/mm |
EN1627-EN1630 Forced entry resistance |
EN1063 Bullet resistance |
UL752 Bullet resistance |
TRD-1 |
2.5-15
|
47.5-70
|
RC3 |
B1-B7
|
Level 1-8
|
TRD-2 | RC4 | ||||
TRD-3 | RC6 |
TR Security Glass Sliding Door System
Design examples
Single leaf:
Minimum Size: Width = 800mm, Height = 1800mm
Maximum Size: Width = 2000mm, Height = 2500mm
Fixed panel:
Maximum Size: Calculate based on the wind load in the project area, building height, and building load-bearing capacity.
TR Security Glass Sliding Door System
Section examples
Types |
Thickness of bullet proof steel plate/mm |
Thickness of Glass/mm |
EN1627-EN1630 Forced entry resistance |
EN1063 Bullet resistance |
UL752 Bullet resistance |
TRS-1 |
2.5-15
|
47.5-70
|
RC3 |
B1-B7
|
Level 1-8
|
TRS-2 | RC4 | ||||
TRS-3 | RC6 |
Авторские права @ 2024 Компания КФОРТС Безопасности Технологии, ООО Все права защищены. ПОДДЕРЖИВАЕМАЯ СЕТЬ